Cause | Remedies |
---|---|
Powder cloud too large. | Operate with precisely aimed powder stream. Choose the right type of nozzle. |
Spacing between the objects too big. | Use a gap control. |
Shape of Object | Work with PCC Mode Use SuperCorona® ring |